HomeProductsUPS > VFI

VFI Systems

Inexpensive UPS systems for protection against most network failures

Why use a UPS?

1. You prevent hardware damage caused by voltage sags and spikes. Many UPS models deliver a continuous supply of incoming power.

2. It prevents data loss and data distortion. Without UPS, system data can be corrupted or even lost completely by a sudden uncontrolled shutdown. Used together with a power management software, the UPS can guarantee a controlled system shutdown.

3. It delivers full network and application availability by avoiding downtimes. UPSs can also be used together with power generators to allow sufficient time to boot the generators in the event of a power failure.

The power needed by an UPS system can be calculated by applying a simple rule of thumb. The power of the connected supply in watts is multiplied by a 1.4 factor to obtain the required VA (Volt ampere) specification.
Example:
1000 Watt power supply pack equals: 1000 Watt x 1.4 = 1400 VA
Therefore, in this case, a 1400 VA system.

  Brief description Specification Links

68180

Eaton UPS device, online, 700 VA, 6 min. bridging time
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm): 440 x 490 x 131
Product details
Data Sheet

68181

Eaton UPS device, online, 1000 VA, 8 min. bridging time
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
153 x 440 x 242
Product details
Data Sheet

68182

Eaton UPS device, online, 1000 VA, 8 min. bridging time
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
438 x 483 x 86,5
Product details
Data Sheet

68183

Eaton UPS device, online, 1500 VA, 6 min. bridging time
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
153 x 490 x 242
Product details
Data Sheet

68184

UPS Pulsar RT, online, 1500 VA, 6 min. bridging time
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
438 x 483 x 86,5
Product details
Data Sheet

Pulsar M Series

  Brief description Specification Links

68400

EatonPulsar M 2200 RT, 3RU, bridgingtime 8 minutes at 100%
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
440 x 490 x 131
Product details
Data Sheet

68401

EatonPulsar M 2200 RT, 2RU, bridgingtime 8 minutes at 100%
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
440 x 640 x 86
Product details
Data Sheet

68411

EatonPulsar M 2200 RT, 2RU, bridgingtime 8 minutes at 100%
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
440 x 640 x 86
Product details
Data Sheet

68402

EatonPulsar M 3000 RT, 3RU, bridgingtime 6 minutes at 100%
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
440 x 490 x 131
Product details
Data Sheet

68403

EatonPulsar M 3000 RT, 2RU, bridgingtime 6 minutes at 100%
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
440 x 640 x 86
Product details
Data Sheet

68417

Eaton Pulsar M3000 RT, 2RU, bridgingtime 6 minutes at 100%
Output voltage: 230 V
can be programmed to 200/208/220/240/250 V
50/60 Hz automatic recognition or frequency converter mode
Dimensions (WxDxH in mm):
440 x 640 x 86
Product details
Data Sheet

PW9130/9135 Series

  Brief description Specification Links

PW9130I700T

UPS PW9130i-700T-XL, kVA/kW 1 / 0,9, tower version, bypass
time full/half load 8/19, online UPS system
With output performance factor 0.9, e.g. 3000 VA / 2700 W, bypass time with up to 4 battery modules (EBM) upgradeable, available interfaces, RS232, USB, 1*relay and emergency off, incl. RS323 + USB cable, communication slot for optional BD SNMP or BD relay card, software suite, shutdown and monitoring software Product details

PW9130I2000R

PW9130i-2000R-XL2U; online UPS system with output performance factor 0.9, e.g. 3000 VA/2700 W; complete assembly kit for 19" rackmount installation
bypass time with up to 4 battery modules (EBM) extendable; at 1000+1500VA 6 IEC320/C13 outputs, at 2000+3000VA 8 IEC320/C13 + 1 C19 output, 1 x power connection cable (Schuko plug on IEC320); 2 x EC320/C14 - IEC320/C13, 1 terminal (IEC320 on 3 x Schuko) available interfaces, RS232, USB, 1*relay and emergency OFF, incl. RS323 + USB cable Communication slot for optional BD SNMP or BD relay card Product details

PW9135-6000

PW9135-6000, 6kVA, 50/60 Hz (automatic switchover)
online, with double-converter technology (VFI-SS-111), fixed wiring + (2) C19, (8) C13, 4 min. autonomy time at 100 % load, 3 height units incl. rackmount kit, rack/tower combination model Product details

Accessories

  Brief description Specification Links

66028
Pulsar STS 16 for EX15-30, Pulsar EXtreme 1500-3000, for uninterruptible switching between 2 sinusoidal current generators or UPS systems for improved security of supply of all connected users, 16 A capacity, 19", 1 HE Product details

68438
bypass time with up to 4 battery modules (EBM) extendable; at 1000+1500VA 6 IEC320/C13 outputs, at 2000+3000VA 8 IEC320/C13 + 1 C19 output, 1 x power connection cable (Schuko plug on IEC320); 2 x IEC320/C14 - IEC320/C13, 1 terminal (IEC320 on 3 x Schuko) available interfaces, RS232, USB, 1*relay and emergency OFF, incl. RS323 + USB cable Communication slot for optional BD SNMP or BD relay card Product details

66102
MGE NMC Minislot Web/SNMP Card 2006 for Evolution, Pulsar, Pulsar M, Pulsar MX Product details

66104
MGE MC Minislot RS232/status information card 2006 for UPS Evolution, Pulsar, Pulsar M, Pulsar MX Product details